ModbusRTU

This library creates and parses Modbus Protocol Data Units (PDU). It depends on Electric Imp's CRC16 library to calculate the CRC-16 value of a string or blob.

To use this library, add the following statements to the top of your device code:

#require "CRC16.class.nut:1.0.0"
#require "ModbusRTU.class.nut:1.0.0"

ModbusRTU Class Usage

This is the main library class. All methods and variables inside this class are static.

createReadPDU(targetType, startingAddress, quantity)

This method creates a PDU for readData operations. It takes the following parameters:

Parameter Data Type Required Default Value Description
targetType Constant Yes N/A Refer to the Target Type table, below
startingAddress Integer Yes N/A The address from which it begins reading values
quantity Integer Yes N/A The number of consecutive addresses the values are read from
Type Value Access
Coil MODBUSRTU_TARGET_TYPE.COIL Read-Write
Discrete Input MODBUSRTU_TARGET_TYPE.DISCRETE_INPUT Read Only
Input Register MODBUSRTU_TARGET_TYPE.INPUT_REGISTER Read Only
Holding Register MODBUSRTU_TARGET_TYPE.HOLDING_REGISTER Read-Write

Example

local targetType = MODBUSRTU_TARGET_TYPE.COIL;
local startingAddress = 0x01;
local quantity = 1;

local pdu = ModbusRTU.createReadPDU(targetType, startingAddress, quantity);
server.log(pdu);

createWritePDU(targetType, startingAddress, quantity, values)

This method creates a PDU for writeData operations. It takes the following parameters:

Parameter Data Type Required Default Value Description
targetType Constant Yes N/A Refer to the Target Type table, below
startingAddress Integer Yes N/A The address from which it begins writing values
quantity Integer Yes N/A The number of consecutive addresses the values are written into
values Integer, array ([integer, boolean]), boolean, blob Yes N/A The values written into Coils or Registers

Example

local targetType = MODBUSRTU_TARGET_TYPE.COIL;
local startingAddress = 0x01;
local values = false;
local quantity = 1;

local pdu = ModbusRTU.createWritePDU(targetType, startingAddress, quantity, values);
server.log(pdu);

createReadExceptionStatusPDU()

This method creates a PDU for readExceptionStatus operations. It takes no parameters.

Example

local pdu = ModbusRTU.createReadExceptionStatusPDU();
server.log(pdu);

createDiagnosticsPDU(subFunctionCode, data)

This method creates a PDU for diagnostics operations. It takes the following parameters:

Parameter Data Type Required Default Value Description
subFunctionCode Constant Yes N/A Refer to the ‘Sub-function Code’ table, below
data Blob Yes N/A The data field required by Modbus request
Sub-function Code Value (Hex)
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_QUERY_DATA 0x0000
MODBUSRTU_SUB_FUNCTION_CODE.RESTART_COMMUNICATION_OPTION 0x0001
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_DIAGNOSTICS_REGISTER 0x0002
MODBUSRTU_SUB_FUNCTION_CODE.CHANGE_ASCII_INPUT_DELIMITER 0x0003
MODBUSRTU_SUB_FUNCTION_CODE.FORCE_LISTEN_ONLY_MODE 0x0004
MODBUSRTU_SUB_FUNCTION_CODE.CLEAR_COUNTERS_AND_DIAGNOSTICS_REGISTER 0x000A
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_MESSAGE_COUNT 0x000B
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_COMMUNICATION_ERROR_COUNT 0x000C
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_EXCEPTION_ERROR_COUNT 0x000D
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_MESSAGE_COUNT 0x000E
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_NO_RESPONSE_COUNT 0x000F
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_NAK_COUNT 0x0010
MODBUSRTU_SUB_FUNCTION_CODE.RETURN_SLAVE_BUSY_COUNT 0x0011
*MODBUSRTU_SUB_FUNCTION_CODE.RETURN_BUS_CHARACTER_OVERRUN_COUNT * 0x0012
MODBUSRTU_SUB_FUNCTION_CODE.CLEAR_OVERRUN_COUNTER_AND_FLAG 0x0014

Example

local data = blob();
data.writen(swap2(0xFF00),'w');
local pdu = ModbusRTU.createDiagnosticsPDU(MODBUSRTU_SUB_FUNCTION_CODE.RETURN_QUERY_DATA, data);
server.log(pdu);

createReportSlaveIdPDU()

This method creates a PDU for reportSlaveId operations. It has no parameters.

Example

local pdu = ModbusRTU.createReportSlaveIdPDU();
server.log(pdu);

createMaskWriteRegisterPDU(referenceAddress, AND_Mask, OR_Mask)

This method creates a PDU for maskWriteRegister operations. It takes the following parameters:

Parameter Data Type Required Default Value Description
referenceAddress Integer Yes N/A The address of the holding register the value is written into
AND_mask Integer Yes N/A The AND mask
OR_mask Integer Yes N/A The OR mask

Example

local referenceAddress = 0x0A;
local AND_mask = 0xFFFF;
local OR_mask = 0x0000;
local pdu = ModbusRTU.createMaskWriteRegisterPDU(referenceAddress, AND_mask, OR_mask);
server.log(pdu);

createReadWriteMultipleRegistersPDU(readingStartAddress, readQuantity, writeStartAddress, writeQuantity, writeValue)

This method creates a PDU for readWriteMultipleRegisters operations. It takes the following parameters:

Parameter Data Type Required Default Value Description
readingStartAddress Integer Yes N/A The address from which it begins reading values
readQuantity Integer Yes N/A The number of consecutive addresses values are read from
writeStartAddress Integer Yes N/A The address from which it begins writing values
writeQuantity Integer Yes N/A The number of consecutive addresses values are written into
writeValue Blob Yes N/A The value written into the holding register

Example

local readingStartAddress = 0x01;
local readQuantity = 1;
local writeStartAddress = 0x0A;
local writeValue = blob();
writeValue.writen(swap2(28),'w');
local writeQuantity = writeValue.len() / 2 ;
local pdu = ModbusRTU.createReadWriteMultipleRegistersPDU(readingStartAddress, readQuantity, writeStartAddress, writeQuantity, writeValue);
server.log(pdu);

createReadDeviceIdentificationPDU(readDeviceIdCode, objectId)

This method creates a PDU for readDeviceIdentificationPDU operations. It takes the following parameters:

Key Data Type Required Default Value Description
readDeviceIdCode Constant Yes N/A Refer to the ‘Read Device ID Code’ table, below
objectId Constant Yes N/A Refer to the ‘Object ID’ Code table, below
Read Device ID Code Description
MODBUSRTU_READ_DEVICE_CODE.BASIC Get the basic device identification (stream access)
MODBUSRTU_READ_DEVICE_CODE.REGULAR Get the regular device identification (stream access)
MODBUSRTU_READ_DEVICE_CODE.EXTENDED Get the extended device identification (stream access)
MODBUSRTU_READ_DEVICE_CODE.SPECIFIC Get one specific identification object (individual access)
Object ID Category
MODBUSRTU_OBJECT_ID.VENDOR_NAME Basic
MODBUSRTU_OBJECT_ID.PRODUCT_CODE Basic
MODBUSRTU_OBJECT_ID.MAJOR_MINOR_REVISION Basic
MODBUSRTU_OBJECT_ID.VENDOR_URL Regular
MODBUSRTU_OBJECT_ID.PRODUCT_NAME Regular
MODBUSRTU_OBJECT_ID.MODEL_NAME Regular
MODBUSRTU_OBJECT_ID.USER_APPLICATION_NAME Regular

Example

local readDeviceIdCode = MODBUSRTU_READ_DEVICE_CODE.BASIC;
local objectId = MODBUSRTU_OBJECT_ID.VENDOR_NAME;
local pdu = ModbusRTU.createReadDeviceIdentificationPDU(readDeviceIdCode, objectId);
server.log(pdu);

parse(params)

This method parses the Modbus PDU and returns the result. The value passed into the parameter, params, is a table composed of the following keys:

Key Data Type Required Default Value Description
quantity Integer No N/A The number of coils/register to read from or write into
PDU Blob Yes N/A The PDU to be parsed
expectedResType Constant Yes N/A The expected response type
expectedResLen Integer Yes N/A The expected response length

Example

local quantity = 1;
local pdu = blob();
local expectedResType = ModbusRTU.FUNCTION_CODES.readCoils.fcode;
local expectedResLen = ModbusRTU.FUNCTION_CODES.readCoils.resLen(quantity);
local result = parse({
    "quantity"        : quantity,
    "PDU"             : pdu,
    "expectedResLen"  : expectedResLen,
    "expectedResType" : expectedResType
  });

License

The ModbusRTU library is licensed under the MIT License.