Changelog

Notable public changes to ArIED 61850 are recorded here. The project uses application version numbers in ArIED61850Tester.csproj; release tags and packages should reference the exact ARIEC61850 engine revision used for that build.

Unreleased

Added

  • Product website for GitHub Pages with overview, feature, Smart Control, and architecture pages.
  • Search-engine metadata, canonical URLs, structured software data, sitemap, robots file, web manifest, social-preview artwork, and responsive navigation.
  • Automated landing-page validation for titles, descriptions, canonical URLs, internal links, JSON, XML, SVG, and image alternative text.
  • Documentation hub, security policy, support guide, community conduct policy, UI validation checklist, and structured issue templates.

Changed

  • Rebuilt the public README around the product workflow, engineering capabilities, application/engine boundary, quick start, validation boundary, and support path.
  • Standardized public product metadata on Ari Sulistiono / masarray and version 1.6.6.
  • Updated CI to build against the reviewed ARIEC61850 main integration baseline.
  • Renamed the external-IP audit document as an evidence-based provenance review.
  • Expanded source-clean verification to website, SVG, web manifest, and public wording files.

1.6.6 — Current development version

Added

  • Engine-owned SCL workspace integration requirement for opening common SCL file types and preparing configured-versus-live model workflows.
  • CI compatibility checks for Smart Control and SCL workspace contracts.
  • Portable Windows x64 packaging at version 1.6.6.

Changed

  • Open SCL now depends on the reusable ARIEC61850 workspace service rather than a separate long-term application-owned protocol parser.
  • Product metadata describes SCL-assisted project setup, live MMS discovery, independent multi-IED monitoring, reporting diagnostics, events, and guarded control.

1.6.5

Added

  • Native Smart Control integration through Iec61850ControlService.
  • Typed Direct and Select-Before-Operate workflows for supported DPC, SPC, INC/ISC, BSC, and APC objects.
  • Per-signal Test, interlock, and synchrocheck flags.
  • Two-step confirmation for Open and Close dispatch.
  • Command evidence for control model, service result, CommandTermination, application error, timing, and process feedback.
  • Signal-selection grid sorting, keyboard filtering, visible-row bulk selection, and virtualized large-model behavior.

Changed

  • Removed the application-level generic MMS control-write fallback.
  • Cached control-object sessions per live IED association.
  • Improved semantic Open/Closed handling when command and feedback wire representations differ.

1.6.4

Added

  • Copy Diagnostic report with application/engine version, adapter, endpoint, TCP reachability, association, discovery, and communication-journal context.

Fixed

  • Window shutdown cleanup re-entry that could cause a WPF closing-state exception.
  • Connection documentation distinguishing TCP refusal and timeout from later IEC 61850 association stages.

Historical licensing boundary

Revisions through 0df1007d9538b978edba67218136bc5c4f8019ad remain available under their original terms on branch archive/apache-2.0-final. Current main and current community release packages are GPL-3.0-or-later only. See docs/LICENSING.md.